Transistor Tester LCR-TC1 LCR-TC2 TCR-T7 TC-T7-H Color Display

Multi-function Transistor Tester Capacitor Resistor Diode Triode

SPECIFICATIONS

  • Supply Voltage: Transistor tester
  • Package: SOP
  • Origin: Mainland China
  • Operating Temperature: Transistor tester
  • Model Number: LCR-TC1 LCR-TC2 TCR-T7 TC-T7-H
  • Dissipation Power: Transistor tester

Transistor Tester LCR-TC1 LCR-TC2 TCR-T7 TC-T7-H Color Display Multi-function Transistor Tester Capacitor Resistor Diode Triode

What's the difference between 4 versions?

LCR-T7 / LCR-TC1:color

  • screen / M644 chip, two functions are the same! T7 is slightly faster!
  • The TC1 screen is slightly larger and they are all powered by lithium
  • batteries. In addition to measuring resistance, capacitance, inductance,
  • diodes, MOS transistors, and thyristors, it can also measure additional
  • voltage regulators, infrared decoding (limited for Hitachi(TM) format)

TC-T7-H: is an upgraded version of LCR-T7, the Up-to-date / fastest version

LCR-TC2:

  • is an upgraded version of TC-T7-H. Compared with TC-T7-H, it has upgraded
  • circuit structure, long-lasting battery life, optimized code, resistance
  • is one thousandth (this is related to repeated test consistency, that
  • is, the same resistance is not repeated test There will be changes, and
  • some repeated tests will have errors)

LCR-TC1

Feature:

  • Self-test with automatic calibration
  • Size: 70*90*26m/ 2.71x3.58x1.10 inch
  • Display: TFT Screen, Color Screen
  • Diode Range: less than 4.5V
  • Zener Diode:Transistor Detect Area: 0.01-4.5V
  • Zener Diode Detect Area: 0.01-30V
  • Triac Range: IGT less than 6mA
  • Capacitance: 25pF-100mF
  • Resistor: 0.01-50MΩ
  • Inductance: 0.01mH-20H
  • Power Voltage: 3.7V
  • Power: Built-in Rechargeable Lithium Battery
  • Measurement results using TFT graphic display (160x128)
  • One-button operation
  • Auto power off (timeout setting)
  • Built-in high-capacity rechargeable lithium-ion battery
  • Lithium-ion battery voltage detection
  • Supports Chinese and English

Warning: Built-in lithium-ion battery, it is strictly forbidden to immerse the tester in water or near a heat source!

Warning: For your personal safety, please strictly observe the specifications and precautions for using lithium-ion batteries!

Transistor Detection:

After the power-off state or test is completed, put the test component into the transistor test area of the test socket, press the lock handle, and press the multi-function key, the tester automatically measures, and the measurement result is displayed at the end of the test.

Warning: Always discharge the capacitor before connecting them to the tester! The tester may be damaged before you turn it on!

Warning:

We do not recommend using a tester to measure the battery! The battery voltage must be less than 4.5V, otherwise, the tester may be damaged!

Component placement:

The test socket is divided into transistor and Zener diode test areas, as described in 1.1.

Note: Do not perform other operations during the calibration process to avoid affecting the calibration accuracy!

Packing List:

  • 1 x multifunction TFT transistor tester
  • 1 x electronic component group (sent randomly)
  • 3 x test hook

Short the three test sockets press the multi-function button shortly, and the tester will automatically calibrate.

No other operations are required after disconnecting the short wiring according to the prompt during the calibration process.

 LCR-TC2 Upgraded High Precision Transistor Tester

 

TCR-T7

1.1        Introduction

  • - 160x128 TFT display
  • - Multi-function key
  • - Transistor test area
  • - Zener Diode test area
  • - IR receiver window
  • - Micro USB Charging Interface
  • - Charge indicator LED


1.1        Features

TC-V2.12k is a TFT graphic display Multifunction Tester.
  • l        Transistor Tester
  • -          Automatic detection of Zener diode0.01-30V
  • - Self-test with automatic calibration
  • l        IR decoder
  • -          Support Hitachi IR coding
  • -          IR waveform display
  • -          Infrared receiving instruction
  • l        Other
  • -          Measurement results using TFT graphic display(160x128)
  • -          One key operation
  • -          Auto Power Off(Timeout Settable)
  • -          Built-in high-capacity rechargeable Li-ion Battery
  • -          Li-ion Battery voltage detection
  • -          Support Chinese and English


Warning: Built-in Li-ion Battery, it is strictly prohibited the tester immersed in water, or near a heat source!

Warning: For your personal safety, please strictly comply with the use of Li-ion Battery specifications and precautions!


1         Operating Instructions

1.1        Key operational definitions

Multi-function key has two actions:

l        Short press: Press the key and not less than 10 ms, release the key within 1.5 seconds

l        Long press: Press the key for more than 1.5 seconds

1.2        Power on

In the power-off state, short press the multifunction key, and the tester is turned on and automatically measured.

l        Power on & measurement interface

TC-T7-H

  • 128x128 TFT display
  • Multi-function key
  • Transistor test area
  • Zener Diode test area
  • IR receiver window
  • Micro USB Charging Interface
  • Charge indicator LED

Features:

  • TC-T7-H is a TFT graphic display Multifunction Tester.
  • Transistor Tester:
  • Automatic
  • detection of NPN and PNP bipolar transistors, N-channel and P-channel
  • MOSFETs, JFETs, diodes (including double diodes), N- and P-IGBTs,
  • resistors (including potentiometers), inductors, capacitors, thyristors,
  • triacs and battery (0.1-4.5V)
  • Automatic detection of Zener diode(0.01-20V)
  • Self-test with automatic calibration
  • IR decoder:
  • Support Hitachi IR coding
  • IR waveform display
  • Infrared receiving instruction

Other:

  • Measurement results using TFT graphic display(160x128)
  • One key operation
  • Auto Power Off(Timeout Settable)
  • Built-in high capacity rechargeable Li-ion Battery
  • Li-ion Battery voltage detection
  • Support Chinese and English
  • Performance Parameters:

Multifunction Tester can automatically identify elements and automatic detection of pin layout, and automatic switching range.

The main performance parameters are as follows:



Component

Range

Parameter Description

BJT

-

hFE(DC
Current Gain), Ube(Base-Emitter Voltage), Ic(Collector Current),
Iceo(Collector Cut-off Current (IB=0)), Ices(Collector short Current),
Uf(Forward Voltage of protecting diode) ③

Diode

Forward Voltage <4.50V

Forward Voltage, Diode Capacitance, Ir(Reverse Current) ②

Double Diodes

Forward Voltage

Zener Diode

0.01-4.50V

(Transistor test area)

Forward Voltage, Reverse Voltage

0.01-20V

(Zener Diode test area)

Reverse Voltage

MOSFET

JFET

Cg(Gate Capacitance), Id(Drain Current) at Vgs(Gate to Source Threshold Voltage), Uf(Forward Voltage of protecting diode) ④

IGBT

Id(Drain Current) at Vgs(Gate to Source Threshold Voltage), Uf(Forward Voltage of protecting diode) ④

MOSFET

Vt(Gate
to Source Threshold Voltage), Cg(Gate Capacitance), Rds(Drain to Source
On Resistance), Uf(Forward Voltage of protecting diode) ④

Thyristor

Igt(Gate trigger current )<6mA

Gate trigger voltage

Triac

Capacitor

25pF-100mF

Capacitance, ESR(Equivalent Series Resistance),  Vloss ①

Resistor

0.01-50MΩ

Resistance

Inductor

0.01mH-20H

Inductance, DC Resistance ⑤

Battery

0.1-4.5V

Voltage, Battery Polarity

Note①: Iceo, Ices, Uf displayed only when effective

Note②: Diode Capacitance, Ir(Reverse Current) displayed only when effective

Note③: Displayed only when has protecting diode

Note④: ESR, Vloss displayed only when effective

Note⑤: Measurement of inductors with resistance below 2100Ω

Note①: Iceo, Ices, Uf are displayed only when effective

Note②: Diode Capacitance, Ir(Reverse Current) displayed only when effective

Note③: Displayed only when has a protecting diode

Note④: ESR, Vloss displayed only when effective

Note⑤: Measurement of inductors with a resistance below 2100Ω

  1. FAQ

Question

Cause

Solution

Cannot power on

Built-in Li-ion Battery is dead

Charging the Li-ion Battery, charging methods see section 2.9

Inaccurate measurements

Inaccurate calibration parameters

Please re-calibration, see section 2.4



 

 

 

 

NOTE:

1. Built-in Li-ion Battery, is strictly prohibited that the tester is immersed in water, or near a heat source!

2. For your personal safety, please strictly comply with the use of Li-ion Battery specifications and precautions!

 


 

 

View full details